Descargar Imprimir esta página

Bosch ACS 763 Manual Original página 64

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 124
en
64 | ACS 763/863 | Instructions for use
6.3
Retrieving refrigerant from a vehicle
WARNING: To prevent injuries while
working with the refrigerant, read and
follow the instructions and warnings in this
manual, and wear protective clothing, such
as safety glasses and gloves.
!
Use only new oil to replace the oil removed during
the recovery process.
!
Dispose of the oil according to the law.
1. Remove the tank from the station pulling it straight
out, without rotating or swinging it.
2. Empty the oil drain tank before starting a recovery
operation.
3. Reinstall the oil drain tank with magnetic connection
on the station.
4. Call up the Main Menu.
5. Select
.
6. Enter the service data and confirm with
chapter 6.1).
7. Connect the high pressure (red) and low pressure
(blue) hose to the vehicle A/C system.
8. Open the valve of the connection on each hose
turning the ring nut clockwise.
9. Select
.
"
The station begins the recovery process.
i
The sounds heard indicate the opening and closing
of the solenoid valve and are normal.
10. If the refrigerant analyzer is installed, the station
verifies that the refrigerant contained in the cylinder
is R1234yf and is not contaminated.
« The display shows
REFRIGERANT ANALYZER
INITIALIZATION
ANALYSIS
i
If the machine detects a problem with the
refrigerant contained in the cylinder, refer to the
Refrigerant Analyzer section in this manual.
11. The station performs a self-cleaning cycle to clean
the internal hoses from refrigerant traces, if any.
12. The function stops when the refrigerant is fully
recovered.
13. After the recovery, the machine performs an oil
drain procedure, which may take up to 90 seconds
to be completed.
|
SP00D00490
2019-03-05
(see
and
REFRIGERANT SAMPLE
14. After the oil is drained, the display shows the result
in which the recovered refrigerant and the drained
oil are described.
i
Select
to print the recovery information and the
result of the diagnosis before the recovery process.
Select
to return to the Main Menu.
!
The recovered and displayed weight may vary
depending on the environmental conditions and
must not be used as an indication of scale accuracy.
i
Exhausted oil separated from the recovered
refrigerant of the vehicle flows into the dedicated
tank.
i
The air conditioner compressor oil is filled with that
the new oil tank (PAG or POE).
15. The amount of oil extracted from the A/C system
is equal to the amount of new oil that can be
introduced into the A/C system at the end of the
vacuum.
"
The recovery is completed.
Robert Bosch GmbH

Publicidad

loading

Este manual también es adecuado para:

Acs 863Acs 863-oe