7.2
Diagnostics for welding problems
Welding problems:
Low welding output.
High welding output.
Erratic welding output
8 Technical specifications
8.1
Operating conditions
The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
8.2
Welding set capacity
8.2.1 Generating set
Before connecting and operating the unit, calculate the electrical power required by the units to be used (in watts)*. To ensure
optimal operation, the total wattage of all equipment used at the same time must be:
-
greater than 60% of the rated load for the unit (risk of insufficient load);
-
less than the rated load for the unit during continuous operation (risk of overload).
If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused
in this way will not be covered by the warranty.
*
This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment requires a higher
load when starting. This minimum required power must not exceed the unit's maximum power
Possible causes:
The settings for the controls are correct.
YES
The unit speed is correct.
YES
The welding connections are correct.
YES
No equipment is connected.
YES
Have the unit checked by one of our agents*.
The settings for the controls are correct.
YES
The unit speed is correct.
YES
The welding connections are correct.
YES
No equipment is connected.
YES
Have the unit checked by one of our agents*.
The settings for the controls are correct.
YES
The unit speed is correct.
YES
The welding connections are correct.
YES
No equipment is connected.
YES
Have the unit checked by one of our agents*.
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
.
21/144
Solutions to be applied:
Check the settings for the controls.
Have the unit checked by one of our
agents*.
Check the welding connections.
Disconnect any equipment from the
sockets before starting.
Check the settings for the controls.
Have the unit checked by one of our
agents*.
Check the welding connections.
Disconnect any equipment from the
sockets before starting the unit.
Check the settings for the controls.
Have the unit checked by one of our
agents*.
Check the welding connections
Disconnect any equipment from the
sockets before starting the unit.
*France: 0.806.800.107 (call charge).