8
Disassembly and disposal
9
Maintenance
10
Technical specifications
Sensing range (with reflector PL40A)
Sensing range max. (with reflector PL40A)
Light spot size / distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Communication mode
IO-Link
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
8025303.1DTW /2022-02-14 | SICK
Subject to change without notice
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
•
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
•
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
WLD4F
0.02 m ... 4 m
0.01 m ... 5 m (Typ)
Ø 37 mm (1,5 m) (Typ); Ø 48 mm
(2,0 m) (Typ)
DC 10 ... 30 V
1)
≤ 5 VSS
≤ 100 mA
25 mA
COM2
1.1
1000 Hz
2)
≤ 500 μs
3)
IP66, IP67
III
A, B, C, D
4)
O P E R A T I N G I N S T R U C T I O N S | WLD4F
8
en
29