DISPLAY SET-UP
The heat counter has a liquid crystal display
with 8 figures and special letters. There are
three information levels:
a) Main level
b) Technical level
c) Statistical level
DISPLAY
1. Main level
1) Total energy consumption in MWh
(standard display)
2) Display function test.
All segments must be displayed at the
same time.
3) Value read on a specific date.
The value alternates with the date itself
4) Total volume in m
3
2. Technical level
1) Maximum power in kW
2) Maximum flow in m
3) Input temperature in °C
4) Output temperature in °C
3. Statistical level
11) Date of previous reading alternating with the corresponding value
(energy).
1)
Until the end of the month, the consumption data and the date are displayed as 0.
2)
It can be set with the appropriate software A password is required, which is provided by the supplier.
64
The information is recalled by pressing
the button below the display
The standard display gives the total ener-
gy consumption from commissioning.
A short press of the button will scroll
through the information at each level.
The main level is automatically displayed
first. By pressing the button for more
5) Instantaneous power in kW
6) Instantaneous flow in m
7) Actual date
1)
8) Error message
(alternating binary and hexadecimal
display)
5) Difference in temperature in °C
3/h
6) Days of operation of the limit valve
7) Impulse value/litre
than 4 seconds, you can move through
the different levels. Release the button to
see the information of the required level.
This way, it is possible to explore all the
information of all the levels.
After 1 minute of non-use, the display
returns to the
standard screen.
9) Tariff register 1: alternating register and
parameter values
3/h
10) Tariff register 2: alternating register
and parameter values
11) Instantaneous reading of the impulse
count 1, alternating with impulse values.
12) Instantaneous reading of the impulse
count 2, alternating with impulse values.
8) M-bus address
9) ID number
10) Firmware/software version
2) -16) Display of the 15 monthly values alternating with
the corresponding date (energy)
2)