PROBLEM
Pressure
reading on
the regulated
pressure
gauge drops
when an
accessory is
used.
knocking
Noise.
compressor is
not supplying
enough air
to operate
accessories.
regulator
knob has
continuous air
leak.
regulator will
not shut off air
outlet.
N015838
CAUSE
It is normal for "some"
pressure drop to occur.
Possible defect in safety
valve.
Defective check valve.
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Restricted air intake filter.
Damaged regulator.
Damaged regulator.
If there is an excessive
amount of pressure drop when
the accessory is used, adjust
the regulator following the
instructions in the Description
of Operation paragraph in the
Operation section.
NOTe: Adjust the regulated
pressure under flow
conditions (while accessory is
being used).
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Remove and clean, or replace.
Decrease amount of air usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if required.
Remove and clean, or replace.
Tighten fittings.
Clean or replace air intake
filter. Do not operate the
air compressor with the
filter removed. Refer to the
Air Filter paragraph in the
Maintenance section.
Replace.
Replace.
20- ENG
CORRECTION