Descargar Imprimir esta página

Cooke & Lewis CLCIN65 Manual De Instrucciones página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
211859_s1_s3-5059340186696-C&L-A5-IM-Easy-V01-Multi.pdf, Cycle:1, Status:Approved
Installation
EN
Electrical installation
All installation must be carried out by a competent person or qualified electrician. Before connecting the
mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct connection
The appliance must be connected directly to the mains using an omnipolar circuit breaker with a minimum
opening of 3 mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it complies with
the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power cord for damage. If the supply cord becomes damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
This appliance should be connected directly to the consumer unit with a 32 Amp Residual Current Device
(RCD) protecting its circuit.
The wires in the mains lead are coloured in accordance with the following code:
Brown / Black = L – Live
Blue = N – Neutral
Green and Yellow =
WARNING: Securely crimp the two Live cables together (L1 and L2) before
WARNING: Before obtaining access to the terminals, all supply circuits must
To avoid the risks that are always present when you use an electrical appliance it is important that this
appliance is installed correctly and that you read the safety instructions carefully to avoid misuse and
hazards. Please keep this instruction booklet for future reference and pass it on to any future owners.
After unpacking the appliance please check that it is not damaged. If in doubt, do not use the appliance
but contact Customer Services - see end of Care & Maintenance section for details.
211859_s1_s3-5059340186696-C&L-A5-IM-Easy-V01-Multi.indd 18
211859_s1_s3-5059340186696-C&L-A5-IM-Easy-V01-Multi.indd 18
Printed by Fang Yuan, 18/03/2021 03:03:03
WARNING: This is a Class I appliance and MUST be earthed.
– Earth
connecting them to the Live terminal of the mains supply.
be disconnected.
32 A~
220-240 V~ 50Hz
13-01-2021 08:30:35
13-01-2021 08:30:35
page 19 of 98 pages
18

Publicidad

loading

Este manual también es adecuado para:

5059340186696