Descargar Imprimir esta página

SICK RAY10 Manual De Instrucciones página 36

Ocultar thumbs Ver también para RAY10:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
OPERATING INSTRUCTIONS
en
9
Disassembly and disposal
10
Maintenance
36
O P E R A T I N G I N S T R U C T I O N S | RAY10
LED/fault pattern
Switching outputs do not
behave in accordance with
table 5
The blue LEDs are very close
together
Yellow LED flashes
Signal interruptions when
object is detected
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces and housing
Check the fittings and plug connectors
Cause
IO-Link communication
Change of the configuration
Short-circuit
Front screen and/or reflector
is contaminated.
Distance between sensor
and reflector is too large /
light beam is not completely
aligned to the reflector /
reflector is not suitable/Front
screen and/or reflector is con‐
taminated.
Depolarizing property of the
object surface (e.g., tape),
reflection
Measures
None
Adjustment of the configura‐
tion
Check electrical connections
Cleaning of the optical surfa‐
ces (sensor and reflector).
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
reflector. / Clean the optical
surfaces (sensor and reflec‐
tor). / Reflector is not suitable
for the application in question
(we recommend only using
SICK reflectors) / Check sens‐
ing range and adjust if neces‐
sary
Reduce sensitivity or change
the position of the sensor
8022198.1G8F/2023-03-29 | SICK
Subject to change without notice