1.4
Product description
1.5
Operating and status indicators
1.6
Mounting
1.7
Electrical installation
8017852.1HW2/2022-11-14 | SICK
Subject to change without notice
2
1
3
2
3
4
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
NOTE
Note the sensor's maximum permissible tightening torque of 0.56 Nm.
Operation in standard I/O mode:
The sensors must be connected in a voltage-free state (U
tion must be observed depending on the connection type:
–
Plug connection: pin assignment
–
Cable: wire color
Only apply voltage/switch on the voltage supply (U
tions have been established.
The green LED indicator on the top of the sensor lights up.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and inte‐
grate in the master or control via IODD/function block. The green LED indicator flashes
on the sensor. IODD and function block are available to download from
under the part number.
Explanation of connection terminology used in Tables 1-3:
OPERATING INSTRUCTION
Potentiometer adjustment (if
1
selected by model configuration) or
LED Indicators
Green LED: supply voltage active
2
(with IO Link, flashes when IO Link
Communication is active)
Yellow LED: status of received light
3
beam (with IO Link, when teach
mode is active)
Signal strength light bar (if selected
4
by model configuration)
= 0 V). The following informa‐
V
> 0 V) once all electrical connec‐
V
O P E R A T I N G I N S T R U C T I O N | HL18(L), HL18G/HL18T
www.sick.com