Pin orientation depends on the sensor angle position.
Table 5: Pilot valve data
Operating voltage
Tolerance
Power consumption
Switch indication
Degree of protection
Table 6: Pin assignment of pilot valve
Pin
1
4
3
1
3
4
7.4 Throttle module: adjusting the throttle
Danger of overturning the adjustment screw!
Damage to the throttle module!
Never turn the adjustment screw firmly all the way to the stop (maximum
u
tightening torque: 0.5 Nm).
Throttle modules come in uni-directional and bi-directional versions. You can
identify the version by the symbol (23) on the front.
Operating lines 2 and 4 can be reduced independent of each other.
To set the flow in the operating line you must set the adjustment screws for con-
nections 2 or 4.
Uni-directional flow
on connection 2 and 4 (±20 %)
(R422003267)
500
450
Unregulated
400
350
300
250
200
150
100
Regulated
50
0
0
1
2
3
4
5
Number of rotations
Fig. 17: Flow diagram for throttle module
1. Use a 5 mm Allen key to turn the adjustment screw (21, 22) counterclockwise
to increase the flow.
The setting in the end stop corresponds to the maximum possible flow.
Turn the adjustment screw clockwise to reduce the flow.-
2. If necessary, secure the adjustment screw with a cover plate (24) and/or a
cover sticker (26).
AVENTICS™ | R422003121-BAL-001-AE | English
24 V DC (bipolar)
+/-10 %
0.8 W
LED, yellow
IP65
Assignment
0 V / 24 V DC
na
24 V / 0 V DC
NOTICE
Bi-directional flow on
connection 2 and 4 (±20 %)
(R422003578)
450
400
350
300
250
200
150
100
50
0
6 7
0
1
2
3
Number of rotations
= 1,2 Nm ±0,2
SW 2,5
21
22
Fig. 18: Throttle module
21
Adjustment screw for connection 2
23
Symbol for the type of throttle
25
Screw to fasten the cover plate
27
Symbol for uni-directional flow direc-
tion
The throttle module and the air circuit should be tested monthly to en-
sure they function correctly.
8 Disposal
Comply with national regulations regarding disposal.
u
9 Troubleshooting
Contact one of the addresses found under http://www.emerson.com/
contactus.
Regulated
10 Technical Data
Table 7: General data
4
5
6 7
General data
Operating temperature range
Storage temperature range
Electrically operated shutoff module temper-
ature range
Working pressure min./max.
Min./max. operating pressure (UL/CSA appli-
cation)
Max. pilot air pressure of electrically operated
shutoff module
Pressure regulator adjustment range
Setting range of the throttle module
Permissible medium
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15 °C below the ambient and medium tempera-
tures and must not exceed 3 °C.
The oil content of compressed air must remain constant during the service life.
u Use only the approved oils from AVENTICS.
26
25
24
27
23
28
22
Adjustment screw for connection 4
24
Cover plate to prevent changes to the
adjustment screw
26
Cover sticker
28
Symbol for bi-directional flow direc-
tion
-10 ... 60 °C
–25 °C ... 80 °C
0 ... 50 °C
0 / 10 bar
0 / 8 bar
7 bar
0.5 / 10 bar
See
g Fig. 17
Compressed air
40 µm
0 ... 5 mg/m3
18