Operating Instructions
Safety Switch STA-TW... (Twin)
Auxiliary key release with state
indication
Function as for auxiliary release.
Important!
The actuator must not be under tensile stress
f
during manual release.
The position of the guard locking is indicated in
the window.
Pos. 1
(normal
operation)
Pos. 2
(locked)
Marking
Fig. 1: Auxiliary key release and indication
Emergency release
This permits opening of a locked guard from outside
the danger zone without tools.
Important!
It must be possible to operate the emergency
f
release manually from outside the protected
area without tools.
The emergency release must possess a mark-
f
ing indicating that it may be used only in an
emergency.
The actuator must not be under tensile stress
f
during manual release.
The release function meets all other require-
f
ments from EN ISO 14119.
The emergency release meets the requirements of
f
Category B according to EN ISO 13849-1:2015.
The contacts
are opened when the emergency
release is actuated. A stop command must be
generated with these contacts.
Mounting
NOTICE
Device damage due to improper mounting and
unsuitable ambient conditions
Safety switches and actuators must not be used
f
as an end stop.
Observe EN ISO 14119:2013, sections 5.2 and
f
5.3, for information about mounting the safety
switch and the actuator.
Observe EN  ISO  14119:2013, section 7, for
f
information about reducing the possibilities for
bypassing an interlocking device.
Protect the switch head against damage, as well
f
as penetrating foreign objects such as swarf,
sand and blasting shot, etc.
The specified IP degree of protection is applica-
f
ble only if the housing screws, cable entries and
plug connectors are properly tightened. Observe
the tightening torques.
The locking screw of the auxiliary release must
f
be sealed before setup (with sealing lacquer,
for example).
Changing the actuating direction
NOTICE
It is not possible to change the position of the
entire head unit.
Guard locking ready
for operation
Guard locking
released
Fig. 2: Changing the actuating direction
1. Remove the screws from the actuating head.
2. Set the required direction.
3. Tighten the screws with a torque of 1.5 Nm.
4. Cover the unused actuating slot with the en-
closed slot cover.
Electrical connection
WARNING
Loss of the safety function due to incorrect
connection.
Use only safe contacts (
f
functions.
When choosing the insulation material and
f
wires for the connections, pay attention to the
required temperature resistance and the max.
mechanical load!
Strip the insulation from the ends of the individual
f
wires over a length of 6
contact.
Use of the safety switch as guard locking for
personnel protection
At least one contact
the guard locking state (for terminal assignment,
see Fig. 3).
Use of the safety switch as guard locking for
process protection
At least one contact
with the
symbol can also be used (for terminal
assignment, see Fig. 3).
The following information applies to devices
with cable entry:
1. Use a suitable tool to open the desired inser-
tion opening.
2. Fit the cable gland with the appropriate degree
of protection.
3. Connect and tighten the terminals with 0.5 Nm
(for terminal assignment, see Fig. 3).
4. Check that the cable entry is sealed.
5. Close the switch cover and screw in place
(tightening torque 1.5 Nm).
Function test
Fatal injury due to faults during the function test.
Before carrying out the function test, make sure
f
that there are no persons in the danger zone.
Observe the valid accident prevention regula-
f
tions.
Check the device for correct function after installa-
tion and after every fault.
Proceed as follows:
Mechanical function test
The actuator must slide easily into the actuating
head. Close the guard several times to check the
function. The function of any manual releases (except
for the auxiliary release) must also be tested.
Electrical function test
1. Switch on operating voltage.
2. Close all guards and activate guard locking.
The machine must not start automatically.
¨
It must not be possible to open the guard.
¨
3. Start the machine function.
It must not be possible to release guard locking
¨
as long as the dangerous machine function is
active.
4. Stop the machine function and release guard
locking.
The guard must remain locked until there is no
¨
longer any risk of injury (e.g. due to movements
with overtravel).
It must not be possible to start the machine
¨
function as long as guard locking is released.
Repeat steps 2 - 4 for each guard.
Inspection and service
Danger of severe injuries due to the loss of the
and
) for safety
safety function.
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
 mm to ensure a safe
±1
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
must be used. It signals
correct switching function
f
secure mounting of all components
f
damage, heavy contamination, dirt and wear
f
sealing of cable entry
f
loose cable connections or plug connectors.
f
must be used. Contacts
Info: The year of manufacture can be seen in the
bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety regula-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.