7. Installation of No-Light Cover
7.3
Disengage the LED Light Fixture Assembly 2-Pin Wire
Connector from the Fan Motor Housing 2-Pin Wire
Connector (Figure 34).
Store the LED Light Fixture Assembly and hardware in
a safe place for future use.
7.4
Tuck all the Wires and Connectors onto the Lower
Housing Assembly.
Place the No-Light Cover into the opening of the Lower
Housing Assembly, aligning the Three Flat Areas on the
top edge of the No-Light Cover with the Three Raised
Dimples on the Lower Housing Assembly.
Turn the No-Light Cover Clockwise until it stops
(Figure 35).
NOTE: Periodically check that the No-Light Cover
is seated fully clockwise in the Lower Housing
Assembly.
(Optional) (Continued)
FAN 2-PIN WIRE
CONNECTOR
LED LIGHT FIXTURE
ASSEMBLY 2-PIN WIRE
CONNECTOR
Figure 34
LOWER HOUSING
ASSEMBLY DIMPLES (3)
NO-LIGHT COVER
FLAT AREAS (3)
Figure 35