2. Remove the reservoir cover.
3. Remove the decalcification cartridge.
4. Insert the new decalcification cartridge and press it
firmly into place.
Illustration S
5. Press the steam lever and switch on the device.
6. Keep the steam lever pressed for 7 seconds.
Illustration T
7. After a successful reset, the device flashes green
twice and then switches to heating mode.
8. Press and hold the steam lever for approximately 50
seconds to vent the decalcification cartridge.
Care of accessories
(Accessories - depending on scope of delivery)
Note
The micro fibre cloths are not suitable for dryer.
Note
Observe the instructions on the washing tag when
washing the cloths. Do not use any liquid softeners as
this will affect the ability of the cloths to pick up dirt.
1. Wash the floor cleaning cloths in a washing machine
at a max. temperature of 60 °C.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
WARNING
Risk of electric shock and burns
Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always
dangerous.
Remove the mains plug.
Allow the appliance to cool down.
No steam / little steam although there is sufficient
water in the reservoir
The decalcification cartridge has not been inserted or
has been inserted incorrectly.
Fit the decalcification cartridge and/or check that the
decalcification cartridge sits tightly in the reservoir
and press in again if necessary.
The decalcification cartridge has been removed when
filling with water and/or a new decalcification cartridge
has been fitted
Always leave the decalcification cartridge in the wa-
ter reservoir during filling.
Press and hold the steam lever constantly.
The full steam output is reached after approximately
50 seconds.
The indicator light flashes red at regular intervals
Run time of the decalcification cartridge ends soon.
Fit a new decalcification cartridge, see chapter In-
serting the decalcification cartridge.
No steam although there is sufficient water in the
reservoir. The indicator light flashes red quickly.
Run time for the decalcification cartridge has expired
Fit a new decalcification cartridge, see chapter Re-
placing the decalcification cartridge.
If a new decalcification cartridge has already been
installed and this error still occurs, the reset process
has probably not been carried out correctly. Please
follow the steps below to reset it:
1
Switch off the device.
2
Press and hold the steam lever constantly.
3
Switch on the device and hold the steam lever for 7
seconds until the indicator lights flash green twice.
See chapter Replacing the decalcification cartridge.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Technical data
Electrical connection
Voltage
Phase
Frequency
Degree of protection
Protection class
Device performance data
Heating capacity
Heating-up time
Continuous steaming
Filling quantity
Water reservoir
Dimensions and weights
Weight (without accessories)
Length
Width
Height
Subject to technical modifications.
SC 2 Up-
right
V
127
~
1
Hz
60
IPX4
I
W
1600
Seconds 30
g/min
30
l
0.4
kg
2.7
mm
314
mm
199
mm
1185