INSTRUCTION MANUAL
Model
3BPS ce/8
3BPS ce/11
3BPS ce/13
3BPS ce/17
3BPS2-17 ce 1100W
3BPS3-12 ce 1100W
3BPS2-23 ce 1500W
3BPS3-17 ce 1500W
3BPS2-37 ce 2200W
3BPS ci/8
3BPS ci/11
3BPS ci/13
3BPS ci/17
4BPS2-12 ci 1100W
4BPS6-11 ci 1500W
4BPS4-15 ci 2200W
4BPS6-14 ci 2200W
4BPS8-10 ci 2200W
Table – Maximum input values of voltage (Voc) and current
On cloudy days, periods of lower incidence of sunlight or when there is a reduction in the intensity of sunlight,
the power voltage provided by solar panels will also be reduced. If the power supply voltage is less than the
minimum voltage of the equipment, the motor pump will not operate.
The open circuit voltage (Voc) of the photovoltaic array cannot be higher than the maximum input
voltage mentioned in the table above, otherwise there will be a serious risk of making the motor pump
unusable.
45
Recommended
voltage of the
Controller
photovoltaic
array
(Vmp)
External
37,7
External
75,4
External
113,1
External
113,1
External
150,8
External
150,8
External
226,2
External
226,2
External
301,6
Internal
37,7
Internal
75,4
Internal
113,1
Internal
113,1
Internal
150,8
Internal
226,2
Internal
301,6
Internal
301,6
Internal
301,6
EBARA BOMBAS AMÉRICA DO SUL LTDA.
3BPS ci/ce and 4BPS ci
Maximum
Maximum
input
input
voltage
current
(Vdc)
(A)
100
15
100
15
150
15
150
15
340
15
340
15
430
15
430
15
490
15
100
15
100
15
150
15
150
15
340
15
430
15
490
15
490
15
490
15
N° of
Photovoltaic
panels*
(connected in
series)
1
2
3
*Note:
3
Considering
4
340Wp
4
photovoltaic
6
panels. For panels
6
of different powers,
there may be a
8
change in the
1
number of panels
2
required.
3
3
4
6
8
8