4.2
Connection of the sensor heads
5
Electrical installation
5.1
Notes on electrical installation
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
2
1
Figure 3: Removal
1.
Open the protective cover.
2.
Connect the sensor head to the evaluation unit (listen for the click).
3.
When removing, press down the pin. Pull the sensor head on the connector.
1
Figure 4: Connecting the sensor head
Verriegelungshebel
1
NOTE
Do not attach any sensor heads other than those in the W130L product family.
NOTE
Do not pull on the cable when removing the sensor head.
NOTICE
Equipment damage due to incorrect supply voltage!
An incorrect supply voltage may result in damage to the equipment.
Only operate the device with safety/protective extra-low voltage (SELV/PELV).
The sensor is a device of protection class III.
Only operate the device with an LPS (limited power source) in accordance with
IEC 62368-1 or an NEC Class 2 power supply unit.
NOTICE
Equipment damage or unpredictable operation due to working with live parts!
Working with live parts may result in unpredictable operation.
Only carry out wiring work when the power is off.
Only connect and disconnect electrical connections when the power is off.
OPERATING INSTRUCTIONS
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
en
39