OPERATING INSTRUCTIONS
en
7
Operation
58
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
Table 24: Moving average
Select the number of measurement repeats.
A c n t
1
TOP
Moving average top menu.
...
2 0 4 8
5.7.5 Extreme value memory
Table 25: Extreme value memory
Select the extreme value memory status.
h o L d o F F
TOP
Extreme value memory top menu.
NOTE
Only when the length measurement function is switched on
5.7.6 End analog function configuration
7.Completing the configuration
Elt
Display reverts to the Analog function top menu.
NOTICE
Do not use the sensor without the protective cover.
NOTICE
Do not use the sensor immediately after switching it on (approx. 100 ms).
select and adjust
1
select and adjust
o F F
P E A
b t t
P - P
. The display reverts to the
Configuring. Mov‐
ing average
1/4/8/16/32/64/128/
256/512/1024/2048
. The display reverts to the
Extreme value memory
deactivated.
Maximum value is applied
to the output.
Minimum value is applied
to the output.
Difference value between
min. and max. is applied to
the output.
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice