6.10.1.1
Analog output menu
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
5.7.1 Activating the analog output
Table 21: Activating the analog output
Activates or deactivates the analog output.
A o u t o F F
TOP
Analog function top menu.
↓
5.7.2 Range configuration
Table 22: Range configuration
Assignment of display values to analog output values
S P A n 4 A
TOP
Detailed configuration menu.
Configuration
Applies to changing the display value, applies to digital
change and is for configuration. The display returns to Range
configuration
After setting the 4 mA value, the display automatically
changes to the 20 mA setting.
Maximal assignable display values are: Transmission, regres‐
sive reflection factor or reflection type: 0...4000 (proportion
of received light) Laser line in Lnth mode: 0...3000 (received
light = line width)
↓
5.7.3 Defining invalid measured values
Table 23: Defining invalid measured values
Select a measured value status when measurement is not
c L P c L P
possible.
TOP
Defining invalid measured values menu.
↓
5.7.4 Moving average
select and adjust
o F F
o u t
select and adjust
4 A
2 0 A
select and adjust
c L P
h o L d
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
OPERATING INSTRUCTIONS
. The display reverts to the
Not activated.
Activated.
. The display reverts to the
Set 4 mA.
Set 20 mA.
. The display reverts to the
Sets the output value to
approx. 24 mA.
Retains the last value
before the invalid status.
en
57