13.6 Electrical connection
In order to ensure the safe and trouble-free operation of the device, the following
instructions must be observed for the electrical connection:
 Before connecting the device, compare the connection data (voltage and frequency) on
the rating plate with those of your electrical network. This data must agree in order that
no damages occur in the device
If in doubt, ask your qualified electrician.
 The electrical outlet must be protected by a 16A safety cut-out switch.
 The connection between the device and the electrical network may employ a 3 meter
long (max.) extension cable with a cross-section of 1.5 mm². The use of multiple plugs
or gangs is prohibited because of the danger of fire that is involved with this.
 Make sure that the power cable is undamaged and has not been installed under the
oven or over hot or sharp surfaces.
 The electrical safety of the device is only guaranteed if the device is connected to a
properly installed protective conductor system. Operations using an electrical outlet
without a protective conductor are prohibited. If in doubt, have the house installation
checked over by a qualified electrician.
The manufacturer cannot be made responsible for damages that are caused by a
missing or damaged protective conductor.