G
B
INSTALLATION SUPER 8000 FAST
CHECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
N.B.: Gate features must be uniformed with the standards and laws in force. The door/
gate can be automated only if it is in a good condition and its conditions comply
with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the opposite case it
is necessary to take the appropriate steps, in accordance with EN 12453 point 6.5.1
(for instance; by preventing the operation of the motor when the pedestrian opening is
opened, by installing a safety microswitch connected with the control panel).
- Besides the electrical or mechanical limit switches available on the operators, there must
be, on both ends of the installation, a fixed mechanical stopper which stop the gate in
the unlikely event of ill functioning of limit swithces on the operators. For this reason
the fixed mechanical stopper must be of an adeguate size to withstand the static and
kinetic forces generated by the gate (12) (Fig.2).The guide must be provided with two
mechanical stops at its ends (12) (Fig. 2).
- Gate columns shall have anti-derailment guides on their top (Fig. 3), to avoid the
unintentional gate release. The guide must be provided with two mechanical stops at
its ends (L) (Fig. 2).
N.B.: Eliminate those mechanical stops of the kind described by pic. 3.
No mechanical stop shall be on top of the gate, since mechanical stops are not safe
enough.
Parts to install according to EN 12453 standard
COMMAND TYPE
(out of public area*)
Hold-to-run operation
Impulsive - in sight
(e.g. push-button)
impulsive - out of sight
(e.g. remote)
automatic
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
EMERGENCY RELEASE
To be undertaken after disconnecting power supply.
The operator is irreversible and keeps the door closed even without a lockset.
To open the gate manually, in open the motor cover and turn the knob «A» anti-clockwise.
To restore electric working you have to turn the lever clockwise (Fig. 4).
In order to carry out the manual operation of the gate leaf the followings must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the operator;
- That the physical effort necessary to move the gate leaf should not be higher than 225
N, for doors/gates for private dwellings, and, 390 N for doors/gates for commercial and
industrial sites ( values indicated in 5.4.5 of the EN 12453 norm).
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
Not skilled
persons
Not possible
C and D, or E
C and D, or E
C and D, or E
28
2
3
4