900 either 33 or 37 liters, according to
the model.
You will know the cavity is com-
pletely full when water comes out
of the control drain (Fig. 1 B1).
When filling is complete, simultaneously
close the filling gate valve and the water
control drain in the cavity (Fig. 1-2 B).
Having successfully filled the cavity
with water, proceed filling the pot.
FILLING THE POT / see SECT. IMA-
GES - REF. l)
Make sure that the cooking compart-
ment drainage gate valve is at the
"Closed" position (Fig. 3).
The drainage gate valve opens
by lifting the handle and turning
it 90°/180° (Fig.3A -3B) respect
to the closed position (Fig.3).
Lift the lid of the pot and fill the co-
oking compartment with the material
to be processed.
When filling the cooking com-
partment, respect the level indi-
cated on the inside (see IMG
REF. l)
Do not introduce large pieces of
kitchen salt into the cooking com-
partment as it deposits at the bot-
tom and does not completely dissolve.
Do not put salt in cold water.
SEE SECT. IMAGES - REF. m)
Hot or cold water can be introdu-
ced into the cooking compartment
by acting on the 2 knobs (Fig.4).
In order to fill the cooking compart-
ment with water, you must:
Lift the lid of the cooking compart-
•
ment if necessary.
Turn the pipe in the direction of the
•
cooking compartment (Fig. 5).
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
INSTRUCTIONS FOR USE
Open the water filling knob at the
•
desired position (hot-cold-both) (Fig.
4A) and fill the tank as needed.
Close the knob/s when filling is com-
•
plete (Fig.4B).
Reposition the pipe so it does not
•
get in the way of the lid when it clo-
ses (Fig. 5).
SWITCHING ON/OFF / see SECT.
IMAGES - REF. m)
The appliance must be swi-
tched on after having filled the
cavity with water. Do not switch
it on when empty (see previous page).
The appliance must be swi-
tched on after having filled the
cooking compartment with wa-
ter. Do not switch it on when the co-
oking compartment is empty.
Left knob = left heating element
Right knob = right heating element
During operation, check the le-
vel of the water inside the co-
oking compartment and bring it
to the correct level as needed by
acting on the water filling knobs.
Having successfully performed the wa-
ter filling operations, proceed with the
"Switch On/Off" procedure as follows:
Turn the switch-on knob to "1-2-3"
•
as required. The green indicator light
will turn on signalling the operating
phase (Fig. 6 A).
Turn the knob to "Zero" (Fig. 6 B) to
•
switch the appliance off at the end of
the work cycle.
OPERATING CONTROL CAVITY /
see SECT. IMAGES - REF. n)
In the estimated models :
During operation, check the le-
vel of the water using the visual
display (Fig.8)
The pressure inside the cavity is
detected by the pressure gauge
placed on the valve (Fig. 7C). If
- 16 -