Descargar Imprimir esta página

SOMFY 5054415A Manual De Instalación página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
The fi gure below illustrates the dimensions to be defi ned for installation.
P
A
Key:
A-B: dimensions used to determine where to fi t the post mounting bracket P
C: distance between mounts (recommended value: 805 mm)
X: distance from the gate centreline to the post edge
Z: distance between the post edge and the motor rotation centreline
α°: gate opening angle
P: post mounting bracket
D: gate section length
F: gate section mounting bracket.
Fitting the post mounting bracket
Defi ne the desired opening angle
Measure the
X dimension on the gate.
Calculate
B = Z + X given that Z = 110 mm
From the table, choose
A and B dimensions that are close to identical
so as to match the opening speed and ensure proper motor drive operation.
If the chosen dimensions are too far apart, gate section motion will not be
constant and the push or pull torque applied will vary during motion.
The table shows the optimum values for A and B for the various "α°" opening angles.
A 100
B
110
130
103
106
140
102
105
150
101
104
160
100
103
170
100
102
180
99
102
190
98
101
200
98
101
210
97
100
220
97
100
230
96
99
240
96
99
250
95
98
260
95
98
Values of "A" and "B" can be chosen from the table based on the desired degree of opening "
Copyright © 2008 Somfy SAS. All rights reserved.
X
B
Z
C
"α°".
120
130
140
150
110
112
116
118
109
111
113
117
108
110
112
116
106
109
112
114
105
108
111
113
104
107
110
112
104
107
109
111
103
106
108
110
103
105
107
109
102
104
106
108
101
104
105
97
101
103
101
91
100
102
91
100
92
D
F
160
170
180
190
121
123
126
124
120
122
124
119
118
120
123
112
117
119
121
106
116
118
109
102
114
117
103
98
113
107
99
95
112
100
95
91
103
95
91
95
91
°
Z = 110
X
B
A
200
210
220
230
113
107
103
99
109
103
99
97
105
100
96
94
101
97
94
92
98
94
91
94
91
91
α°
α°
".
5

Publicidad

loading

Este manual también es adecuado para:

Ixengo l