Descargar Imprimir esta página

SOMFY 5054415A Manual De Instalación página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING TEST
Opening the gate by hand
If necessary, the motor drive unit is provided with a release key so that the gate section can be moved by hand.
[1] After lifting the lock cover, insert the release key and turn it clockwise by 90°.
[2] Push the gate section by hand to open the gate.
[3] Turn the release key in the opposite direction to return to motor driven operation.
[4] Refi t the lock cover.
Checking operation
Before starting up the motor drive unit:
Check that all components are solidly mounted
Check all safety mechanisms for correct operation
Check the emergency operation control
Check that the electronic controller is operating correctly.
What do I do if the motor drive unit fails?
Use a suitable instrument to check for the presence of voltage on the ends of the motor reduction gear unit after an
opening or closing operation.
If the drive rod does not turn in the right direction, reverse the electrical operating connections on the motor reduction
gear unit.
If the gate reverses direction after opening or closing, this means that the limit stops have not been correctly set. Refer
to the section called "Adjusting the limit stops" to refi ne the position of the limit stops.
SPECIFICATIONS
Power supply
Rotation speed
Power consumption
Current consumption
Push and pull torque
Useful travel
Drive rod speed
Obstacle detection (impact reaction)
Limit stops
Manual operation
Nbr. of operations per 24 hours
Maximum gate section length
Maximum gate section weight
Ambient conditions
Protection level
Lubrication
10
24 V version
24 V DC
3800 rpm
40 W
1.5 A
2000 N
410 mm
14 mm/s
Built-in torque limiter
Built-in, electromechanical and adjustable
By unlocking key
60 operations
4000 mm
400 kg
-10°C to +60°C
IP44
Greased for life
Copyright © 2008 Somfy SAS. All rights reserved.

Publicidad

loading

Este manual también es adecuado para:

Ixengo l