11OFF - "Slave" function disabled (to activate only for coupled connection, see
p.30)
12ON - Partial opening function (automatic closing is fixed at 8 seconds) enabled;
12OFF - Partial opening function (automatic closing is adjusted with the trimmer, if
inserted) enabled;
13ON - Activates safety test that checks the photocells proper operation (see
pag.14) enabled; (13OFF-disabled)
14OFF - "Master" function disabled (to activate only for coupled connection, see
p.30)
15
- Not used, keep the dip in position "OFF"
16ON - Courtesy light function enabled; (16OFF-disabled)
17ON - Lamp cycle function enabled; (17OFF-disabled)
18
- Not connected
19
- Not connected
20
- Not connected
FRANÇAIS
11OFF - Fonction "slave" désactivée (à n'activer que pour le branchement
accouplé, voir page 30);
12ON - Fonction d'ouverture partielle (la fermeture automatique est fixe à 8")
activé
12OFF - Fonction d'ouverture partielle (la fermeture automatique est réglable
au moyen du trimmer, si elle est enclenchée) activé;
13ON - Activation du test de sécurité pour le contrôle du bon fonctionnement
des photocellules (voir pag.14) activé; (13OFF-désactivée)
14OFF - Fonction "master" désactivée (à n'activer que pour le branchement
accouplé, voir page 30);
15
- Pas utilisé, garder le commutateur à bascule sur "OFF"
16ON - Fonction lampe d'éclairage activé;(16OFF-désactivée )
17ON - Fonction lampe cycle activé;(17OFF-désactivée )
18
- Non connecté
19
- Non connecté
20
- Non connecté