Descargar Imprimir esta página

Altrad Belle RPX 35 Manual Del Operador página 28

Ocultar thumbs Ver también para RPX 35:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
The Altrad Belle 'RPX' range of Reversible Plate Compactors are designed to give many years of trouble free operation. It is, however,
important that the simple regular maintenance listed in this section is carried out. It is recommended that an approved Altrad Belle
dealer carries out all major maintenance and repairs. Always use genuine Altrad Belle replacement parts, the use of spurious parts may
void your warranty.
Before any maintenance is carried out on the machine, switch off the engine. If working on a diesel engine, make sure that the stop
switch is in the stop position.
Always set the compactor on level ground to ensure any uid levels will be correctly read. Only use recommended oils (see chart on
following page).
Running In Period
When the compactor is rst used from new, the engine oil must be changed after the initial running in period (see engine manufactur-
er's manual for full detail). The belt tension should be checked after 4 hours use.
Drive Belt
Remove the belt guard then check the belt tension by placing light nger pressure on the top of the belt, as near central between the
engine drive and gearbox pulley. The belt should de ect by approx. 10 to 15mm. If the belt tension requires adjustment, loosen the
setscrew on the Belt Tensioning device and slide to the right. Once set, retighten the setscrew and check belt tension a secong time.
Finally, replace the belt guard ensuring it is correctly and securely tted.
Routine Maintenance
Engine Oil
Air Filter
Spark Plug
Drive Belt
Oil / Fuel Type & Quantity - Spark Plug Type
Honda GX200 Gasoline
Hatz 1B20 Diesel
Oil Type & Quantity
Component
Gearbox
Hydraulic Control
Li-Ion Battery - Charging (Hatz 1B20 Diesel Electric model only)
Use ONLY speci c Li-ion battery chargers
DO NOT charge the battery with charging voltage of over 15.0V
DO NOT use any charger with automatic desulphation function
When possible, remove the battery from the vehicle before charging
Charging voltage should be 14.0 – 15.0V for both vehicle and battery charger. Lower voltage will result in insuf cient charge.
Higher voltage will cause damage to the battery
Respect the standard & maximum charge current indicated on the battery labels
Avoid draining the battery to less than 8V. If the voltage drops to below 8V, refer to the charger manual
If the battery becomes hot to the touch, stop charging and allow the battery to cool before resuming
After charging, wait 1 to 2 hours before checking the voltage. If the voltage is less than 12.8V, additional charging is necessary
Service & Maintenance
Check Level
Change
Check Condition / Clean
Change
Tension
Quantity
Oil Type
S.A.E. 10W 30
S.A.E. 10W 30
Oil Type
S.A.E. 10W 40
Shell Tellus 32
Fuchs Renolin MR520
Every 8
First Month /
50 Hours
Hours
Replace when necessary / Every 12 months
Fuel Type
(Gal)
Unleaded
0.16
Gasoline
Diesel
0.23
(BS2869)
28
150
250
Hours
Hours
Capacity
Spark Plug
(Gal)
Type
BPR6ES
0.82
(NGK)
Refer to
N/A
Manual
Honda GX200
(Gal)
0.19
0.05
0.05
500
Hours
Electrode
Gap (mm)
0.7 - 0.8mm
N/A
Hatz 1B20
(Gal)
0.19
0.05
0.05

Publicidad

loading