Descargar Imprimir esta página

Dacor DOP36P86GLS Manual De Instalación página 28

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions
To adjust flame low setting
Identify which burner is exhibiting too high or too low simmer flame size, adjust
as necessary by following steps below:
Simmer Set
Screw
Small
Screwdriver
Valve Stem
WARNING
1.
Do not completely remove the valve set screw from the valve stem. The valve
set screw is an integral part of the gas valve assembly. Removing the valve
set screw will cause gas to leak.
2.
After adjusting the valve set screw, inspect the assembly for gas leaks.
28 English
Install_DOP36P86GLS_DG68-01106D-00_EN+MES+CFR.indb 28
1.
Rotate a knob to LO position and
remove the knob from the valve stem
while the flame is lit.
2.
Carefully push the screw driver into
the stem of the valve, until it hits
the simmer set screw. Make sure the
screwdriver flathead is seated into the
set screw groove.
3.
Rotate valve set screw clockwise to
decrease LO setting flame output, or
rotate set screw counter clockwise to
increase LO setting flame output.
Memo
2020-07-01 오후 4:07:36

Publicidad

loading