F. "Low Volt" Menu
Screen 13
LOW VOLT
.0
HOURS
MENU
MOTOR
(See Screen 13.) This screen allows the operator to read the
number of hours the pump has been operated in low-voltage
condition. Step forward by pressing the Menu button. See QRC
step #5.
G. "Advance" Menu
Screen 14
ADVANCE
188
HOURS CYCLES
MENU
MOTOR
(See Screen 14.) This screen allows the operator to read the number
of hours (On/Off cycles) the Advance solenoid has been operated.
Toggle between hours and cycles by pushing either the Down or Up
Arrow buttons. Step forward by pressing the Menu button. See
QRC step #6.
H. "Retract" Menu
Screen 15
RETRACT
334
HOURS CYCLES
MENU
MOTOR
(See Screen 15.) This screen allows the operator to read the
number of hours (On/Off cycles) the Retract solenoid has been
operated. Toggle between hours and cycles by pushing either the
Down or Up Arrow buttons. Step forward by pressing the Menu
button. See QRC step #7.
I. "Local" Menu
Screen 16
SET
OFF
MENU
MOTOR
(See Screen 16.) This screen allows the operator to toggle the
LOCALmode ON or OFF, default is OFF. With LOCAL mode ON, the
shroud buttons replace the pendant buttons as the method to
operate the pump (NOTE: The word "LOCAL" replaces "OK" on the
"Normal Operations" display and the pendant buttons become
deactivated). LOCAL mode will provide operation of the pump if the
pendant or pendant cord is damaged. Toggle LOCAL mode ON or
OFF by pressing the Down (Up) Arrow button. Save setting and step
forward by pressing the Menu button. See QRC steps #8 and #9.
J. "Language" Menu
Screen 17
ENGLISH
SET
MENU
MOTOR
(See Screen 17.) With a language shown on the text display the
operator can change the display language by pressing the Down
(Up) Arrow buttons. Save setting and step forward by pressing the
Menu button. See QRC step #10.
K. "Diagnose" Menu
Screen 18
DIAGNOSE
SET
00001
MENU
MOTOR
Pendant DOWN ARROW button
Pendant UP ARROW button
Pendant ON/OFF button
(See Screen 18.) This screen allows the operator to trouble shoot
several pendant problems by displaying if the microprocessor has
8
LOCAL
PSI
(not used)
Fan