Charger
AL 100
Power supply:
120 V / 60 Hz
Rated current:
1.3 A
Power consumption:
75 W
Charge current:
1.6 A
Insulation:
II, E (double
insulated)
AL 300
Power supply:
120 V / 60 Hz
Rated current:
4.7 A
Power consumption:
330 W
Charge current:
6.5 A
Insulation:
II, E (double
insulated)
AL 500
Power supply:
120 V / 60 Hz
Rated current:
4.8 A
Power consumption:
570 W
Charge current:
12 A
Insulation:
II, E (double
insulated)
Cutting attachment
Cutting swath:
FSA 65:
11.8 in
(300 mm)
FSA 85:
13.8 in
(350 mm)
FSA 65, FSA 85
Length
FSA 65:
60 in
(1530 mm)
FSA 85:
65 in
(1650 mm)
Weight
without battery, with cutting attachment
and deflector
FSA 65:
6.0 lbs
(2.7 kg)
FSA 85:
6.2 lbs
(2.8 kg)
Transporting Batteries
STIHL batteries comply with the
requirements set forth in UN-Manual
ST/SG/AC.10/11/Rev.5/Part III,
Subsection 38.3.
Commercial air, vessel and ground
transportation of lithium ion cells and
batteries is regulated. The battery is
classified as a UN 3480, Class 9,
packaging group 2 product. Shipping it,
either as a complete tool or the battery,
requires compliance with all applicable
shipping regulations. Check with the
ground, vessel, air cargo or passenger
airline to determine if transport is
prohibited or subject to restrictions or
exemptions prior to shipping or travel.
Normally, no further conditions have to
be fulfilled by the user to transport
STIHL batteries by road to the power
tool's operating site. Check and comply
with any special regulations that may
apply to your situation.
FCC 15 Compliance Statement for
Power Tool and Charger
This device complies with part 15 of the
FCC Rules. Operation is subject to the
following two conditions:
this device may not cause harmful
–
interference.
this device must accept any
–
interference received, including
interference that may cause
undesired operation.
Note: This equipment has been tested
and found to comply with the limits for a
Class B digital device, pursuant to part
15 of the FCC Rules. These limits are
designed to provide reasonable
protection against harmful interference
in a residential installation. This
equipment generates, uses and can
radiate radio frequency energy and, if
not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or
television reception, which can be
determined by turning the equipment off
and on, the user is encouraged to try to
correct the interference by one or more
of the following measures:
reorient or relocate the receiving
–
antenna,
increase the separation between
–
the equipment and receiver,
English