Troubleshooting - Stihl FSA 65 Manual De Instrucciones

Ocultar thumbs Ver también para FSA 65:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

Always remove the battery before carrying out any work on the power tool.
Condition
Machine does not start when switched on
Machine cuts out during operation
Runtime is too short
Battery jams when being inserted in machine
/ charger
FSA 65, FSA 85
Cause
No electrical contact between machine
and battery
Battery is low on charge
(1 LED on battery flashes green)
Battery too hot / too cold
(1 LED on battery glows red)
Fault in battery
(4 LEDs on battery flash red)
Machine too hot
(3 LEDs on battery glow red)
Fault in machine
(3 LEDs on battery flash red)
Moisture in machine and/or battery
Battery or machine's electronics too hot Take battery out of machine, allow bat-
Electrical fault
Battery not fully charged
Using unsuitable nylon line
Useful life of battery has been reached
or exceeded
Guides / contacts dirty
Remedy
Remove the battery, visually check con-
tacts and refit battery
Charging the Battery
Allow battery to cool down / at tempera-
tures of about 60°F - 70°F (15°C - 20°C),
allow battery to warm up slowly
Take the battery out of the machine tool
and refit it. Switch on the machine – if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Allow machine to cool down
Take the battery out of the machine tool
and refit it. Switch on the machine – if the
LEDs still flash, the machine has a mal-
function and must be checked by a
1)
servicing dealer
Allow machine / battery to dry
tery and machine to cool down
Remove the battery and refit it
Charge the battery
Replace nylon line
1)
Check battery
and replace
Carefully clean the guides / contacts
English
27

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Fsa 85