OPERATION
TROUBLESHOOTING
PROBLEM
No machine power.
Brush motor(s) do not operate.
Vacuum motor(s) do not operate.
Machine does not propel or
propels incorrectly.
Scrub head will not lower.
No solution spray or solution spray
is uneven.
24
CAUSE
Key turned off.
Tripped main power circuit breaker.
Discharged batteries.
Loose or disconnected battery cable.
Expired battery life.
Control grips not rotated.
Tripped brush motor circuit breaker(s). Determine cause and reset breaker.
Solution switch is turned off.
Low voltage interrupter activated.
Loose or broken belt.
Faulty brush motor or wiring.
Worn carbon brushes in motor.
Scrub head is raised off floor.
Low voltage interrupter activated.
Blown fuse.
Faulty vacuum motor or wiring.
Worn carbon brushes in motor.
Solution switch is turned off.
Tripped drive motor circuit breaker.
Faulty potentiometer or speed control
board.
Faulty drive motor or wiring.
Worn carbon brushes in motor.
Wire #47 is not connected to batteries.
Low voltage interrupter activated.
Control grips not rotated.
Solution switch is turned off.
Scrub head not lowered.
Solution tank is empty.
Wrong rear vacuum shoe installed.
Clogged spray tips.
Plugged solution tank filter.
Clogged solution line.
Faulty pump or solenoid.
Home
Find... Go To..
SOLUTION
Turn key on.
Reset breaker.
Recharge batteries.
Secure battery cable connections.
Replace batteries.
Rotate control grips forward.
Solution switch must be turned on to
activate brush motors.
Recharge batteries.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Lower scrub head.
Recharge batteries.
Replace fuse. (#768688 -- 30A Fuse)
Contact Service Center.
Contact Service Center.
Solution switch must be activated
when ReadySpace cleaning.
Determine cause and reset breaker.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Connect wire #47 to battery as shown
in battery cable connection label.
Recharge batteries.
Rotate control grips to activate spray.
Turn on solution switch.
Lower Scrub Head.
Refill solution tank.
Install correct vacuum shoe.
Clean spray tips.
Clean solution tank filter.
Flush plumbing system.
Contact Service Center.
Tennant 1610 (11- -05)