Descargar Imprimir esta página

RIB DUKE B2D 24V-CRX Manual De Instalación página 38

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
CAUTION: FOR ONE MOTOR CONTROL DIP 12 MUST BE POSITIONED TO ON; DURING
PROGRAMMING THE POWER SENSOR IS CONTINUOUSLY ACTIVE.
The gate must be completely closed.
1 - Set DIP 2 to ON => LED DL1 will blink rapidly.
2 - Press the PROG button. => M1 opens.
When the mechanical opening stopper is reached, the impact sensor stops M1
(memorizing time and current levels absorbed along the travel).
3 - Press the PROG button. => M1 closes.
At the same time LED DL1 stops flashing indicating exit from programming. Safety and
other gate commands now operate normally (inversions, stop, alarms, etc.).
Upon closing the impact sensor stops the gate.
4 - AFTER PROGRAMMING RE-SET DIP 2 TO OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE "MOTOR ROTATIONAL DIRECTION CONTROL" AND REPEAT THE DESIRED
PROGRAMMING PROCEDURE.
E - SETTING PEDESTRIAN OPENING TIMES (#)
With gate closed:
1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON (LED DL1 flashes
slowly).
2 - Push the pedestrian button (COM A+/PED.) => M1 opens.
3 - Push the pedestrian button to stop movement (thereby setting M1 opening).
4 - Push the pedestrian button to start closing.
5 - Upon closing reset DIP 1 and 2 to OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP THE
PROGRAMMING PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE
PROCEDURE "MOTOR ROTATIONAL DIRECTION CONTROL" AND REPEAT THE DESIRED
PROGRAMMING PROCEDURE.
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING
(1000 CODES MAX) - with radio module ACG8069
ATTENTION: before storing the radio codes, use DIP 13 to select which transmitters to use:
DIP 13 OFF: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
SUN-PROX 2CH 2-channel - red keys and yellow led cod. ACG6220
SUN-PROX 4CH 4-channel - red keys and yellow led cod. ACG6224
DIP 13 ON (default): You can store transmitters with fixed code SUN and MOON:
SUN 2CH 2-channel - blue keys and white led cod. ACG6052
SUN 4CH 4-channel - blue keys and white led cod. ACG6054
SUN CLONE 2CH 2-channel - blue keys and yellow led cod. ACG6056
SUN CLONE 4CH 4-channel - blue keys and yellow led cod. ACG6058
MOON 2CH 2-channel - black keys and yellow LED cod. ACG6081
MOON 4CH 4-channel - black keys and yellow LED cod. ACG6082
ATTENTION: it is not possible to memorize at the same time transmitters with fixed code and
transmitters with variable code.
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 seconds.
2 - Press the TRANSMITTER button (usually channel A) within the allotted 10 seconds. If
the remote is memorized properly LED DL12 blinks green and a buzzer tone confirms
the correct memorization. The 10 seconds for programming the codes are automatically
renewed, with LED DL12 which flashes red, in order to store the next transmitter.
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED DL12
stops flashing.
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
ALL RADIO CODES FOR TOTAL OPENING CANCELLATION PROCEDURE
Cancellations can only be performed when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - LED DL12 flashes red for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
green flashes of LED DL12 and 2 tones of the buzzer.
4 - LED DL12 flashes red again for 10 seonds and you can add new codes as shown above.
5 - Re-set DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR TOTAL OPENING)
Indication is visible only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The LED DL12 flashes green 6 times when the memory is full (1000 codes). Now LED
DL12 blinks red for 10 seconds enabling possible cancellation of all codes.
3 - Re-set DIP 1 to OFF and DIP 2 to OFF.
4 - End of procedure.
G - RADIO CODES PROGRAMMING PROCEDURE FOR PEDESTRIAN
OPENING (1000 CODES MAX) - with radio module ACG8069
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON. DL12 flashes green for 10 seconds.
2 - Press the transmitter button (usually channel B) within the allotted 10 seconds. If the
transmitter is properly memorized LED DL12 blinks red and the buzzer emits a tone. The
10 seconds are automatically renewed (DL12 flashes green) in order to memorize next
transmitter.
3 - To finish programming wait 10 seconds, or press the PROG button briefly. The LED DL12
stops flashing.
4 - Reset DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
ALL RADIO CODES FOR PEDESTRIAN OPENING CANCELLATION PROCEDURE
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON. LED DL12 flashes green for 10 seconds.
2 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
red flashes of LED DL12 and two tones of the buzzer.
3 - The red LED DL1 remains active and you can add new codes as shown above.
4 - Reset DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR PEDESTRIAN OPENING)
Indication is visible only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - LED DL12 flashes green 6 times if the memory is full (1000 codes). LED DL12 blinks red
for 10 seconds enabling possible cancellation of codes.
3 - Set DIP 1 to OFF and DIP 3 to OFF.
4 - End of procedure.
H - PROGRAMMING RADIO CODES (FOR R-AUX RELAY) (1000 CODES
MAX) - with radio module ACG8069
* Remote control management can be enabled only by the RIB GATE app.
R-AUX normally works as a courtesy light for 3 minutes.
Through the RIB GATE app it is possible to configure the operation of this relay as
desired.
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON, DIP 2 to ON and then DIP 3 to ON. DL12 flashes orange for 10 seconds.
2 - Press the transmitter button (usually channel C) within the allotted 10 seconds. If the
transmitter is properly memorized LED DL12 blinks green and the buzzer emits a tone.
The 10 seconds are automatically renewed (DL12 flashes orange) in order to memorize
next transmitter.
3 - To finish programming wait 10 seconds, or press the PROG button briefly. The LED DL12
stops flashing.
4 - Reset DIP 1, 2 and 3 to OFF.
5 - End of procedure.
RADIO CODES CANCELLATION PROCEDURE (FOR R-AUX RELAY)
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON, DIP 2 to ON and then DIP 3 to ON. LED DL12 flashes green for 10
seconds.
2 - During these 10 seconds press and hold the PROG button for 5 seconds. Memory
cancellation is indicated by two green flashes of LED DL12 and two tones of the buzzer.
3 - LED DL12 blinks orange again for 10 seconds and you can add new codes as shown
above.
4 - Re-Set DIP 1, 2, 3 to OFF.
5 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR R-AUX RELAY)
38

Publicidad

loading

Este manual también es adecuado para:

Abb2060Abb2061Ac08072