Descargar Imprimir esta página

Stihl RT 4082.1 Manual De Instrucciones página 106

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 299
14.16 Removing the steering column
cover
● Stop the engine. (
12.3)
● Engage the parking brake. (
● Remove the ignition key and keep it in a
safe place.
Press both retaining lugs (1) inwards
slightly and hold. Pull steering column
cover (2) downwards and remove.
14.17 Installing the steering column
cover
● Stop the engine. (
12.3)
● Engage the parking brake. (
● Remove the ignition key and keep it in a
safe place.
104
8.10)
Insert cover (1) into dashboard (2) from
below. To do this, first fit the cover in the
area of the dashboard and then press it
into the final position.
Make sure that guides (3) are correctly
positioned inside the black cover and
inside the dashboard. The snap-in
hooks (4) must engage in wing (5).
14.18 Fuses
Fire hazard!
Never bypass the fuses with wire or
foil.
Never use a fuse with a value that
differs from the specified rating
(ampere).
8.10)
If a new fuse blows within a short
time, an electrical fault (e.g. short
circuit) is the probable cause.
A specialist dealer should be
consulted. STIHL recommends
STIHL specialist dealers.
● Stop the engine. (
● Engage the parking brake. (
● Remove the ignition key and keep it in a
● Remove the steering column cover.
Plug-in fuses:
Nominal current: 10 A
Remove plug-in fuses (1). Visually check
whether wire (2) in the plastic is damaged
(burnt through).
Replace the fuse if wire (2) is damaged.
Main fuse:
Nominal current: 150 A
12.3)
safe place.
(
14.16)
0478 193 9905 B - EN
8.10)

Publicidad

loading

Este manual también es adecuado para:

Rt 40826140