Special Functions; Adding Or Subtracting Measurements; Retrieving Or Deleting Data From Data Memory - Hilti PD-I Manual Del Usuario

Ocultar thumbs Ver también para PD-I:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Aim the laser at the third target point.
6. Press the
button.
▶ Measurement has been completed.
The following values are shown on the display:
• Second length
• Third length
• Calculated result
6.2.6
Using the Layout function
1. Use the
and
2. Press the
button to confirm the value.
3. Take the measurement by passing the laser range meter along the layout baseline.
The following values are shown on the display:
• Distance between the nearest layout point and the wall
• Distance from the nearest layout point
An acoustic signal sounds inside a range of 10 cm from the nearest layout point.
A different acoustic signal sounds when the layout point is reached (display shows 0.000).
A minus sign (-) in front of the value indicates that you have to move away from the wall.
4. Press the
button to end measurement.
6.3

Special functions

6.3.1

Adding or subtracting measurements

You can use the "Add/Subtract" function to add or subtract the measured values of different functions.
The following functions are compatible:
• Measure distance
• Measuring area
• Measure volumes
• Pythagoras (2-point)
• Pythagoras (3-point)
1. Use one of the compatible functions.
2. Press the
button if you want to add a new measured value or press the
subtract.
3. Take another measurement.
If you are using the "Measure distance" function, the result appears automatically. If you are using
the Area, Volume or Pythagoras function, you have to press the
regular process of measurement.
The following values are shown on the display:
• Previous measurements
• Sum of/difference between measurements
6.3.2

Retrieving or deleting data from data memory

The product can save a maximum of 10 measured values in its data memory.
Every subsequent measurement automatically deletes the oldest measured value.
1. Press the
button.
▶ The 10 most recent measured values are displayed.
10
English
10
buttons to set the distance between the layout points.
button if you want to
button after completing the
2222191