Modify Presets
To modify a preset, recall the preset with the desired output configuration, modify the Input parameters, Output parameters, then save the preset. In
addition, you can save the preset as you are going thru the creation process.
Recall a Preset
A Preset includes the output configuration, input parameters, and loudspeaker profiles (DSP, load, and assignments). There are 20 factory presets that
can be recalled, but not overwritten, and 50 user-defined presets that can be recalled and overwritten.
• Factory presets F1: Config thru F9: Config contain output configurations only.
• Factory presets F10: thru F20: contain the output configurations and basic DSP for the configurations.
• There are 50 user presets that can be recalled and overwritten.
Recalling a Preset changes the configuration of the amplifier. You can recall factory or user-defined presets.
HOME > PRESETS > PRESET RECALL (ENTER)
Step 1 — Select Preset
F1: A B C D
F1: A B C D
EN
M
Input
Step 2 — Confirm Selection
F1: A B C D
F18: 3-Way
M
Press ENTER to confirm selection
TD-000434-00-B
M
M
M
A
B
C
Sub
LF
MF
HF
M
M
A+B
C
Indicates more Presets
D
Full
D
The message at the bottom changes to: "Recalling Preset now..."
You may hear relays clicking!
17
Scroll to desired Preset
20 Factory, 50 User-defined
To select the Preset configuration, press
To confirm the selection, press
ENTER
ENTER