Descargar Imprimir esta página

QSC DPA4.2 Manual Del Usuario página 22

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
HOME > OUTPUTS > SPKR PROC > LIMITER
Step 1 — Gain Reduction
F1: A B C D
Outputs
DELAY
LIMITER
Limiter Params
ARRAY
Step 2 — Set the Limiter Mode
F1: A B C D
EN
AUTO
Set AUTO Mode Parameters
NOTE!: SpkrPwr maximum output depends on the amplifier and the output configuration you select. The maximum for separate
channels is 1250 W, a single combined channel (ABCD or AB+CD) can be up to 5000 W depending on the amplifier.
HOME > OUTPUTS > SPKR PROC > LIMITER > AUTO
Step 1 — Set the AUTO Mode Parameters
F1: A B C D
AUTO
Type - the Auto Limiter Type is a protection level and its values are, Mild, Medium and Aggressive. This Type parameter, along with the Power Rating
and Impedance drive an algorithm designed to maximize the performance of your loudspeakers. They set the RMS and Peak threshold values as well
as their attack and release setting.
SpkrPwr - if a single speaker is being driven, the SpkrPwr should be the continuous power rating of that loudspeaker. If multiple speakers are being
driven this value should be the combined power rating for the load.
SpkrImp - if a single speaker is being driven, the SpkrImp should be the nominal impedance of that loudspeaker. If multiple speakers are being
driven this value should be the combined impedance for the load.
TD-000434-00-B
Output
A
Gain Reduction
0.0 dB
Press Enter to Edit
XO
EQ
DL
LM
LM
AC
Output
A
Type
SpkrPwr
SpkrImp
Med
200W
8.0
Output
A
Type
SpkrPwr
SpkrImp
Med
200W
8.0
The Gain Reduction currently
being applied to the selected
Output channel.
AUTO
Type:
Scroll to select (Type, SpkrPwr, SpkrImp)
Aggressive
Medium
Mild
SpkrPwr:
10.0 W to 1250 KW
SpkrImpd:
2.0 Ω to 16.0 Ω
22
To edit the Limiter settings, press
To edit the Limiter mode, press
Turn to select the mode for the Limiter
ADV
OFF
To confirm setting, press
To edit, press
Turn to adjust parameter
To confirm, press
To exit, press
ENTER
ENTER
ENTER
ENTER
ENTER
EXIT