3.10.1.2 Low Battery Warning – Non-Display Keypad
Keypads without a display will provide the following indicators as a Low Battery Warning:
Upon wake-up and at the end of an open sequence, the Keypad will emit 2 high beeps and 2 green LED
flashes, followed by 2 low beeps and 2 red LED flashes.
3.10.2 Critical Low Battery Warning
Critical Low Battery Warning indicates that the system will not respond to any other commands until the
battery is replaced.
3.10.2.1 Critical Low Battery Warning – Display Keypad
Keypads with a display will provide the following indicators as a Critical Battery Warning:
Upon wake-up, the Keypad will emit 3 high beeps and 3 green LED flashes, followed by 3 low beeps and
3 red LED flashes.
The screen will display "Critical Low Battery" on wake-up.
3.10.2.2 Critical Low Battery Warning – Non-Display Keypad
Keypads without a display will provide the following indicators as a Critical Battery Warning:
Upon wake-up, the Keypad will emit 3 high beeps and 3 green LED flashes, followed by 3 low LED beeps
and 3 red LED flashes.
3.10.3 Replacing Batteries in Critical Low Battery State
When in Critical Low battery state, and the batteries are within the secure container, the system must do a
restart when a battery (or batteries) is applied to the Keypad. The restart can be forced by pressing the # key
when the new battery is applied to the Keypad. The safe should be opened and the inside batteries replaced.
Note: If the Time/Date is not set after a prolonged power outage, access time lock schedules cannot be
enforced and may result in the inability to open the lock until the Time/Date is set.
3.11 View Audits (Display Keypad Only)
Note: This function is not UL evaluated.
Audits can be viewed on Keypads equipped with a display. A maximum record of 50 events can be viewed on
the Keypad display screen. The Keypad will display:
The code indicating the Event/Action
The Date and Time of the Event/Action
The ID of the User who performed the Action
To view audits from the display, the User must have Audit Privileges enabled. The Master User ID is granted
Audit Privileges by default.
Follow these steps to view Audits on screen:
1.
Enter an Authorized User ID and Combination.
2. Navigate through the Main Menu and select "Audits".