6. "Success Mode Updated" appears on screen and the Keypad will beep three times and flash a green LED
once complete.
3.14.1.3 Enable/Disable Time Delay – Non-Display Keypad
Note: This function is not available on the 701 series of Keypad.
Follow these steps to Enable/Disable Time Delay, set the Time Delay Period, and set the Confirmation Window
on a non-Display Keypad:
1.
Using the Keypad, input #72 + Authorized ID and Combination + Delay Period (00 to 99 minutes) +
Confirmation Window (01 to 60 minutes) + <return key> (←).
2. The Keypad will beep three times and flash a green LED once complete.
3.14.2 Open a Lock During Time Delay
3.14.2.1 Open a Lock During Time Delay – Display Keypad
Follow these steps to open a safe lock during a Time Delay on a Display Keypad:
1.
Using the Keypad, input the User ID and Combination.
2. For multi-lock systems, select the corresponding lock number on the keypad. Otherwise, skip to the next
step.
3. "Lock # Start Delay" will appear on screen and provide timer feedback. The type of feedback depends on
the setting for count feedback (the time may count down, up, or only show time remaining). A key must be
pressed to check the Time Delay status. When a key is pressed on a Display Keypad, the 'most urgent' lock
will be displayed.
a)
Most Urgent Lock: In a single lock system, the Time Delay status is for a single lock, in a multi-
lock system, the status will be provided for i) the lock with the least amount of time remaining in
the confirmation window, or ii) if no lock is in the confirmation window, then the lock with the
least amount of time remaining will be present in the delay window
4. Once the Time Delay period expires, "Lock # status Confirm" appears on screen.
5. If a lock is in the confirmation window, it can be opened. Press a key to exit the Time Delay Status.
6. Input the User ID and Combination.
7. From the sub-menu, select "Open Lock".
a)
For multi-lock systems, select the corresponding lock number on the keypad. If the selected lock
has Time Delay enabled and i) is not already in Time Delay, Time Delay will start for the lock, and
ii) is already in Time Delay and the confirmation window, then the lock will open
8. The lock will open, and the screen will display "Lock Open". After a few seconds, the lock will close.
3.14.2.2 Open a Lock During Time Delay – Non-Display Keypad
Note: This function is not available on the 701 series of Keypad,
Follow these steps to open a safe lock during a Time Delay on a non-Display Keypad:
1.
Using the Keypad, input the User ID and then the Combination.
2. The Keypad will beep and flash a red LED once every 10 seconds during the Time Delay period.
3. The Keypad will then beep and flash a green LED once every 10 seconds during the Confirmation Window,
signifying the safe lock can now be opened.