Operation
Fill fresh water reservoir
CAUTION
Risk of damage. Only use the recommend-
ed detergents. With other detergents, the
operator bears the increased risk regarding
the operational safety, risk of accident and
reduced service life of the appliance. Only
use detergents that are free of solvents, hy-
drochloric acid and hydrofluoric acid.
Follow the safety instructions for using de-
tergents.
ATTENTION
Do not use highly foaming detergents.
Observe the dosing notes.
Recommended detergents:
Application
Everyday cleaner,
alkali-based
Everyday cleaner,
acidic, for sanitary
applications, swim-
ming pools, etc. Re-
moves limestone
deposits.
Wipe care EXTRA RM 780
Floor base cleaner,
acidic
Remove the fresh water reservoir from
the appliance.
Open the cover of the fresh water reser-
voir.
Pour in water/detergent mixture. Maxi-
mum temperature of the liquid 50 °C.
Close the cover of the fresh water res-
ervoir.
Insert the fresh water container into the
appliance.
Detergent Dosage
CA 50 C
0,2 - 1,0%
RM 738
0,5 - 3,0%
0,5 - 2,0%
RM 751
1,0 - 25%
ATTENTION
Risk of damage to the floor covering. The
cleaning method for heavy soiling must
only be used on floors suitable for this kind
of cleaning.
Risk of damage to the fresh water pump if it
runs dry because of empty fresh water
tank. Monitor the filling level display and
switch the water pump switch off if the fresh
water tank is empty.
ATTENTION
Risk of damage to the battery. If the LED of
the battery charge indicator flashes during
cleaning, work must be interrupted and the
battery charged.
Normal soiling
Illustration
Set the suction bar lifting pedal to the
"suction" position ("1/ON" position).
Press the park position release and
swivel the handle toward the rear.
Press the switch for brushing/vacuum-
ing operation.
Activate the water pump switch.
Move the appliance over the surface to
be cleaned.
Severe soiling
Illustration
Set the suction bar lifting pedal to the
"no suction" position ("0/OFF" position)
and carry out cleaning as for normal
contamination. The cleaning fluid re-
mains on the surface to be cleaned and
has time to take effect.
Move the vacuum bar lift pedal to posi-
tion "suction off" and reclean the sur-
face.
Complete cleaning
Turn off the water pump switch.
Push the appliance a little further to
vacuum up the remaining water.
Press the switch for brushing/vacuum-
ing operation.
Swivel the appliance handle forward
and arrest in the park position.
– 3
EN
Cleaning
13