5. Using intelligent terminals
5.1
Intelligent terminal lists
Nombre
Simbolo
del
terminal
terminal
Forward
FW
RUN/STOP
(0)
terminal
Reverse
RV
RUN/STOP
(1)
terminal
CF
(2)
CF
(3)
Multi-speed
frequency
commanding
terminal
CF
(4)
CF
(5)
JG
Jogging
(6)
2-stage
2CH
acceleration
(8)
/deceleration
FRS
Free-run stop
(9)
EXT
External trip
(10)
USP
Unattended start
(11)
prevention
SFT
Terminal soft-
(12)
ware lock
AT
Current input
(13)
selection
RS
Reset
(14)
Signal source
CM1
for input
External power
P24
supply terminal
for input
del
SWF switch
ON(closed) :Forward run
OFF(open) : stop
SWR switch
ON(closed) :Reverse run
OFF(open) :stop
1
2-speed
1-speed
2
Switch
ON
CF1
3
CF2
FW
RV
4
Jogging operation
The acceleration or deceleration time is possible to change considering
the system.
The inverter stops the output and the motor enters the free- run state.
(coasting)
It is possible to enter the external trip state
Restart prevention when the power is turned on in the RUN state.
The data of all the parameters and functions except the output frequency is
locked.
The [AT] terminal selects the inverter uses the voltage [O] or current [OI]
input terminals for external frequency control.
If the inverter is in Trip Mode, the reset cancels the Trip Mode.
Common terminal for intelligent input terminals.
External power connection terminal for intelligent input terminals.
Descripción
SWR
RV
CM1
2
0-speed
3-speed
ON
ON
ON
ON
ON
[4-Stage speed]
5-1
SWF
FW
SWF
ON
1
SWR
OFF
RS
AT
CM1
6
5
Default terminal setting
ON
Terminal1 : FW
Terminal 2 : RV
Terminal 3 : CF1
Terminal 4 : CF2
Terminal 5 : AT
Terminal 6 : RS
Forward
Reverse
OFF
OFF
ON
OFF
CF2
CF1
FW
RV
4
3
2
1