Standard operator option code
Set the parameter [ C01 ~ C06 ] to [ A11 ~ A25 ], F01
Option
Terminal
Code
Symbol
Valid for inputs:
Required setting
Notes :
• When programming the multi-speed
setting sure to press the Store key each
time and then set the next multi-speed setting.
Note that when the key is not pressed,
no data will be set.
• When a multi-speed setting more
than 50Hz(60Hz) is to be set, it is necessary
to program the maximum frequency
A04 high enough to allow that speed.
• While using the multi-speed capability, you can monitor the current frequency with monitor
function F01 during each segment of a multispeed operation.
There are two ways to program the speeds into the registers A20 to A25
Programming using the CF switches, Set the speed by following these steps
(1) Turn the Run command off(Stop Mode).
(2) Turn each switch on and set it to Multi-speed n. Display the data section of F01.
(3) Set an optional output frequency by pressing the
(4) Press the (STR) key once to store the set frequency. When this occurs, F01 indicates the
output frequency of Multi-speed n.
(5) Press the (FUNC) key once to confirm that the indication is the same as the set frequency.
(6) When you repeat operations in (1) to (4), the frequency of Multi-speed can be set.
It can be set also be parameters A11 to A25
Function Name
State
C01,C02,C03,C04,C05,C06
F01, A11 to A25
Description
Example:
and
keys.