Two-stage Acceleration and Deceleration [2CH]
• When terminal [2CH] is turned on, the
inverter changes the rate of acceleration
and deceleration from the initial settings F02
(acceleration time1) and F03(deceleration time1)
to use the second set of acceleration / deceleration values.
• When the terminal is turned off, the equipment is turned off,
the equipment is returned to the original acceleration and deceleration time
(F02 acceleration time1 and F03 deceleration time1).
Use A54 (acceleration time2) and A55 (deceleration time2) to set the second
stage acceleration and deceleration time.
• In the graph shown above, the [2CH] becomes active during the initial
acceleration. This causes the inverter to switch form using acceleration
1 ( F02 ) to acceleration 2 ( A54 )
Option
Terminal
Code
Symbol
8
2CH
Valid for inputs:
Required setting
Notes:
• Function A56 selects the method for second
stage acceleration.
It must be 00 to select the input terminal method
in order for the 2CH terminal assignment to
operate.
Input
Function Name
State
Two-stage
Acceleration
and Deceleration
C01,C02,C03,C04,C05,C06
A54, A55, A56
Frequency output uses 2nd-stage acceleration and
ON
deceleration values
Frequency output uses the initial acceleration
OFF
1 and deceleration 1 values
Example:
5-9
[FW,RV]
[2CH]
Output
frequency
Description