Setting Method
(1)Digital panel
No
Name
Auto-tuning
H01
mode selection
H02
Motor data setting
H03
Motor capacity
H04
Motor poles
Rated
H05
motor current
No Load
H06
motor current
Rated
H07
motor slip
Motor resistor
H08/H10
R1
Transient
H09/H11
Inductance
Note. The data of H10 to H11 is auto-tuning data.
Setting range
0 : Auto-tuning OFF
0/1
1 : Auto-tuning ON
0 : Standard data
0/1
1 : Auto-tuning data
2.2L : 220V / 2.2kW
3.7L : 220V / 3.7kW
5.5L : 220V / 5.5kW
7.5L : 220V / 7.5kW
18.5L : 220V / 18.5kW
-
2/4/6/8
Unit : pole
0.1 – 320.0
Unit : A
0.1 – 200.0A
Unit : A
0.01 – 10.00%
Unit : %
Unit : Ω
0.001~30.00
0.01~100.0
Unit : mH
5-25
Description
11L : 220V / 11kW
15L : 220V / 15kW
22L : 220V / 22kW
30L : 220V / 30KW
2.2H : 380V / 2.2kW
3.7H : 380V / 3.7kW
5.5H : 380V / 5.5kW
7.5H : 380V / 7.5kW
11H : 380V / 11kW
15H : 380V / 15kW
18.5H : 380V / 18.5kW
22H : 380V / 22kW
30H : 380V / 30kW
37H : 380V / 37kW
45H : 380V / 45kW
55H : 380V / 55kW
75H : 380V / 75kW
90H : 380V / 90kW
110H : 380V / 110kW
132H : 380V / 132kW
160H : 380V / 160kW