Function Description; Function Setting - Hyundai N700E Manual De Instrucciones

Tabla de contenido

Publicidad

N700E INSTRUCTION MANUAL
Auto-tuning(1)

Function description

The auto-tuning procedure automatically sets the motor parameter related to sensorless vector control.
Since sensorless vector control needs motor parameter, the standard motor parameters have been set
at the factory.
Therefore, when an inverter exclusive-use motor is used or when a motor of any other manufacture is
drive, the motor parameter is detected by auto-tuning because the parameters are not matched.

Function setting

Follow the steps below to auto-tune the inverter, finally set the parameter H01.
F02, F03 setting : Set the time the range that over-current or over-voltage trip event not occurs.
H03 setting : Set the motor rating.
2.2L : 220V / 2.2kW
3.7L : 220V / 3.7kW
5.5L : 220V / 5.5kW
7.5L : 220V / 7.5kW
11L : 220V / 11kW
15L : 220V / 15kW
18.5L : 220V / 18.5kW
22L : 220V / 22kW
30L : 220V / 30kW
H04 setting : set the motor poles
A01 setting : set the frequency command source to 0 (potentiometer)
A03 setting : set the base frequency(example 60Hz)
F01 setting : set the operation frequency except 0hz (by the potentiometer)
A53 setting : select output voltage for motor.
A33 setting : set DC braking setting to 0(disable).
H01 setting : select the auto-tuning mode (2).
After setting above parameters, press the RUN key on the standard operator.
Set the same as setting F02.
2.2H : 380V / 2.2kW
3.7H : 380V / 3.7kW
5.5H : 380V / 5.5kW
7.5H : 380V / 7.5kW
11H : 380V / 11kW
15H : 380V / 15kW
18.5H : 380V / 18.5kW
22H : 380V / 22kW
30H : 380V / 30kW
37H : 380V/37kW
45H : 380V/45kW
55H : 380V/55Kw
75H : 380V/75kW
90H : 380V/90kW
110H : 380V/110kW
132H : 380V/132kW
160H : 380V/160kW
5-23