Descargar Imprimir esta página

American Standard 7441381 Manual Del Propietário página 8

Llave de cocina retráctil electrónica

Publicidad

Idiomas disponibles

Idiomas disponibles

10
SERVICE
Battery needs replacement:
Sensor will start to blink continuously every second.
This is the indication that the batteries are low in
power.
• Replace batteries in battery holder with Qty (4) AA
alkaline type batteries.
• Batteries last approximately one year.
• Always change all 4 batteries. Failure to replacing
all 4 batteries at the same time may cause faucet
electronics to not work properly.
Reduced or distorted flow:
Debris or dirt accumulating at inlet or AERATOR
MAY CAUSE REDUCED OR DISTORTED FLOW.
A) Clean inline filter at inlet hoses.
B) Turn hot and cold water supply off. Open valve
in mixed position for two seconds to relief
pressure close valve.
C) Disconnect inlet hoses at stop valve and clean
screen filter. If necessary remove inline filter and
rinse at another water source.
Aerator Clean Out
• AERATOR may accumulate dirt causing distortion
and reduced water flow. Remove AERATOR by
using the Aerator key (9) and rinse to clear any
debris.
• Clean out the SCREEN (10) by removing
SPRAY HEAD (11).
Power failure (manual bypass):
• In the event of a power failure, turn the BYPASS
KNOB (1) on the SOLENOID ASSEMBLY (2) to
the "ON" position. The faucet will be in MANUAL
MODE (see section 5) and the handle can be used
to turn on and off the water.
11
CARE INSTRUCTIONS
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL
CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
11
9
1
INLINE FILTER
2

Publicidad

loading

Este manual también es adecuado para:

7442381743838170773807418381