Fitting And Removing Accessory Tools; Removing The Accessory Tool - Hilti DCG 180-D Manual Del Usuario

Ocultar thumbs Ver también para DCG 180-D:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
6.5

Fitting and removing accessory tools

CAUTION
Risk of injury. The accessory tool may be hot.
▶ Wear protective gloves when changing the accessory tool.
Diamond discs must be replaced when their cutting or grinding performance drops significantly. This
generally is the case when the diamond segments reach a height of less than 2 mm (1/16").
Other discs must be replaced when their cutting performance drops significantly or other parts of the
angle grinder (not the disc) come into contact with the material you are working on.
Abrasive discs must be replaced when their expiry date has been reached.
6.6
Fitting an accessory tool
1. Disconnect the supply cord plug from the power outlet.
2. Check that the O-ring is in place in the clamping flange and that it is undamaged.
Result
The O-ring is damaged.
There is no O-ring in the clamping flange.
▶ Fit a new clamping flange with O-ring.
3. Fit the clamping flange onto the drive spindle.
4. Fit the accessory tool.
5. Screw on the clamping nut corresponding to the type of accessory tool fitted.
6. Press the spindle lockbutton and hold it in this position.
7. Use the pin wrench to tighten the clamping nut securely, then release the spindle lockbutton and remove
the wrench.
6.7

Removing the accessory tool

1. Disconnect the supply cord plug from the power outlet.
CAUTION
Risk of breakage and irreparable damage. If the spindle lockbutton is pressed while the spindle is rotating,
this may cause the accessory tool to work loose or detach from the power tool.
▶ Press the spindle lockbutton only when the spindle has stopped rotating.
2. Press the spindle lockbutton and hold it in this position.
3. Release the clamping nut by gripping it with the pin wrench and turning the nut counterclockwise.
4. Release the spindle lockbutton and remove the accessory tool.
6.8
Fitting an accessory tool secured with a Kwik lock nut
CAUTION
Risk of breakage. Heavy wear (abrasion) may cause the Kwik lock nut to break.
▶ When working with the power tool, make sure that the Kwik lock nut doesn't come into contact with the
working surface.
▶ Do not use a damaged Kwik lock nut.
The optional Kwik lock nut can be used instead of the standard clamping nut. Accessory tools (discs
etc.) can then be changed without need for additional tools (keyless system).
1. Disconnect the supply cord plug from the power outlet.
2. Clean the clamping flange and the quick-release clamping nut.
3. Check that the O-ring is in place in the clamping flange and that it is undamaged.
Result
The O-ring is damaged.
There is no O-ring in the clamping flange.
▶ Fit a new clamping flange with O-ring.
24
English
Printed: 29.03.2018 | Doc-Nr: PUB / 5069492 / 000 / 03
5
6
71878
*71878*

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dcg 180-p