Voltage adjustment
After selected the battery voltage, it is possible to adjust the voltage by 0.1V step according to manufacturer's specifications.
DIAG+ MODE CONFIGURATION
DIAG+
12V
U=13.5V
DIAG+
12V
U=13.5V
DIAG+
24V
U=27.2V
Precaution: Before using the Diag+ Mode. If the screen displays a current greater than 10A, it indicates the battery is discharged.
The device will start charging automatically Check all electrical consumers are switched off on the vehicle. Wait until the current falls
below 10A and then re-launch the diagnostic.
SHOWROOM MODE
On a stationary vehicle, the charger supplies up to 50A to test high-energy consumers (engine fan, window regulator, electronic
suspension, etc...) by supplying a steady voltage adjustable:
- 12V to 14.8V (for 12V battery)
- 24V to 29.6V (for 24V battery)
- 6V to 7.4V (for 6V battery)
Voltage adjustment:
After selected the battery voltage, it is possible to adjust the voltage by 0.1V step according to manufacturer's specifications.
SHOWROOM MODE CONFIGURATION
SHOWROOM
12V
U=13.5V
SHOWROOM
12V
U=13.5V
SHOWROOM
24V
U=27.2V
Start without battery (not recommended)
Possibility to launch the mode without the battery by pressing the START/STOP key for 3 seconds.
The indictation « no battery » displays for 1 second before supplying the power.
Warning: polarity reversal can damage the vehicle electronics.
Precaution
Before using the Showroom Mode. If the screen displays a current higher than 10A, it indicates the battery is discharged. The device
will start charging automatically. Check all electrical consumers are switched off on the vehicle. Wait until the current falls below 10A
before using any electical functions of the car.
CHANGE BATTERY MODE
This charger will maintain a stabilised power supply to the vehicle during battery replacement to preserve memory settings. By default
this mode is inactive and doesn't appear in the mode list. It can be activated via the Advanced menu (see page 16).
GYSFLASH 50-24 HF
6V
12V
24V
6.0V
12.0V
24.0V
6.1V
12.1V
24.1V
...
...
...
7.4V
14.8V
29.6V
6V
12V
24V
6.0V
12.0V
24.0V
6.1V
12.1V
24.1V
...
...
...
7.4V
14.8V
29.6V
Start up :
• Connect the clamps : red to the (+) and black to
the (-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the instan-
taneous voltage are displayed.
STARTING DIAG+
DIAG+
12V
U=13.5V
Start up with battery :
• Connect the clamps : red to the (+) and black
to the (-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the ins-
tantaneous voltage are displayed.
STARTING SHOWROOM
SHOWROOM
12V
13.5V
EN
DIAG+
12V
U=13.5V
I=12A
SHOWROOM
12V
U=13.5V
I=12A
13