ProCore Edge North America
Message/
Name
BATT
UNDER VOLT
Battery under
Voltage
31241-03-0202 Page 58 of 69
Severity Description
The BMID
number of
battery cells
setting is
incorrect.
Fault
The battery
voltage is too
low to start the
fast charge
(the voltage
is below
the battery
table minimum
voltage limit).
The battery is
drained to a
voltage below
a safe level
for charging.
Recovery
charge
is needed.
Webasto Charging Systems, Inc.
IOMM
Action(s)
Use the
ProCore™ App
BMID setup to
set the correct
number of
battery cells.
Press and
hold the
EQ Schedule
button to initiate
a recovery
charge and raise
safely the
battery voltage.