IOMM
Message/
Name
Module OVP
Tripped
MODULE TYPE
ERR
Module
Installation
Type
No Battery
Configuration
Webasto Charging Systems, Inc.
Severity Description
Fault
There was
an error
in the
over-voltage
protection
module.
Fault
The power
module type
does not
match the
factory
configuration
(cabinet
voltage)
settings, or
incompatible
modules were
installed
together.
Fault
The
parameters
have not been
configured for
the voltage
mode charge.
ProCore Edge North America
Action(s)
Check that the
battery voltage
is within range
for the charger.
Install the
correct
power module.
Call Webasto
service.
Configure the
voltage mode
settings on the
charger, using
the ProCore™
mobile app.