ProCore Edge North America
Message/
Name
Module Memory
Issue
Module OCP
Tripped
MODULE
OVER TEMP
Module/
charger over
Temperature
31241-03-0202 Page 64 of 69
Severity Description
Fault
The module
had a memory-
related error.
Fault
There was
an error
in the
over-current
protection
module.
Fault
The air intake
is blocked.
The system
board
temperature
sensor is
above 80°C.
The module
temperature is
too high
to charge.
The module
failed.
Webasto Charging Systems, Inc.
IOMM
Action(s)
Call Webasto
service.
Check that the
battery voltage is
within range for
the charger.
Check for
obstructed
air flow.
Remove the
blockage.
Replace the
power module.