Device settings (All
settings are executed
after holding value for
13
(please read remark
PB 600 IPG2
20CH
Wash
Channel
Function
1
2
3
Strobe Functions
264
128 - 129 PWM 5 (18900 Hz)
130 - 131 PWM 6 (25000 Hz)
132 - 133 RAW
134 - 135 Factory Calibration
136 - 137 User Calibration
138 - 139 Smart Calibration
140 - 141 Display Always On
142 - 143 Display Off after 20s
144 - 163 No function
164 - 165 Dimmer Curve Linear
166 - 167 Dimmer Curve Exponential
3 seconds)
168 - 169 Dimmer Curve Logarithmic
170 - 171 Dimmer Curve S-Curve
1*)
172 - 239 No function
240 - 241 Load Factory Defaults
242 - 243
244 - 245 Load User Default A
246 - 247 Load User Default B
248 - 249 Load User Default C
250 - 255 No function
Values
Dimmer
000 - 255 0% to 100%
Dimmer fine
000 - 255 0% to 100%
000 - 005 Open
006 - 010 Closed
011 - 022 Ramp up/down slow to fast
023 - 033
034 - 045 Ramp up slow to fast
046 - 056
057 - 068 Ramp down slow to fast
069 - 079
080 - 102
Load Factory Defaults (with-
out User Colours & Loops)
Ramp up/down random
slow to fast
Ramp up random
slow to fast
Ramp down random
slow to fast
Random Strobe effect slow
to fast
PWM
Frequency
Color
Calibration
Display
Functions
Dimmer Curve
Load Default
Subgroup
Dimmer
Multi-
functional
Strobe