Device settings (All
settings are executed
after holding value for
20
(please read remark
PB 600 IPG2
44CH
Pattern
Channel
Function
1
2
3
Strobe Functions
268
086 - 119 No function
120 - 121 PWM 1 (650 Hz)
122 - 123 PWM 2 (1530 Hz)
124 - 125 PWM 3 (3600 Hz)
126 - 127 PWM 4 (12000 Hz)
128 - 129 PWM 5 (18900 Hz)
130 - 131 PWM 6 (25000 Hz)
132 - 133 RAW
134 - 135 Factory Calibration
136 - 137 User Calibration
138 - 139 Smart Calibration
140 - 141 Display Always On
142 - 143 Display Off after 20s
3 seconds)
144 - 163 No function
164 - 165 Dimmer Curve Linear
1*)
166 - 167 Dimmer Curve Exponential
168 - 169 Dimmer Curve Logarithmic
170 - 171 Dimmer Curve S-Curve
172 - 239 No function
240 - 241 Load Factory Defaults
242 - 243
244 - 245 Load User Default A
246 - 247 Load User Default B
248 - 249 Load User Default C
250 - 255 no function
Values
Dimmer
000 - 255 0% to 100%
Dimmer fine
000 - 255 0% to 100%
000 - 005 Open
006 - 010 Closed
011 - 022 Ramp up/down slow to fast
023 - 033
034 - 045 Ramp up slow to fast
046 - 056
Load Factory Defaults (with-
out User Colours & Loops)
Ramp up/down random
slow to fast
Ramp up random slow to
fast
PWM
Frequency
Color
Calibration