18 | English
Point and line laser
– Laser lines
– Laser points
Typical self-levelling range
Typical levelling time
Operating temperature
Storage temperature
Max. altitude
Relative air humidity max.
Pollution degree according to
IEC 61010-1
Laser class
Laser line
– Laser type
– Colour of the laser beam
– C₆
– Divergence
Laser point
– Laser type
– Colour of the laser beam
– C₆
– Divergence
Tripod mount
Batteries
Operating duration in operating mode
– Cross-line and point mode
– Cross-line mode
– Line and point mode
– Line mode
– Point mode
Weight according to EPTA-Proced-
ure 01:2014
Dimensions (length × width × height)
– Without rotating mount
– With rotating mount
Protection rating
A) The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight).
B) At 20–25 °C
C) The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Ex-
treme fluctuations in temperature can cause deviations in accuracy.
D) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number (12) on the type plate is used to clearly identify your measuring tool.
Assembly
Inserting/Changing the batteries
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
1 609 92A 8E9 | (20.03.2023)
±0.3 mm/m
±0.7 mm/m
–10 °C to +50 °C
–20 °C to +70 °C
< 1 mW, 630–650 nm
0.5 mrad (full angle)
< 1 mW, 630–650 nm
0.8 mrad (full angle)
3 × 1.5 V LR6 (AA)
B)
112 × 55 × 106 mm
132 × 81 × 163 mm
IP54 (dust and splash-proof)
To open the battery compartment cover (6), press the lock-
ing mechanism (7) and lift open the battery compartment
cover. Insert the batteries.
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
compartment.
GCL 2-15
±4°
< 4 s
2000 m
90 %
D)
2
2
< 10 mW, 500–540 nm
Red
1
50 × 10 mrad (full angle)
< 1 mW, 630–650 nm
Red
1
1/4", 5/8"
6 h
8 h
12 h
16 h
22 h
0.49 kg
IP54 (dust and splash-proof)
GCL 2-15 G
±0.3 mm/m
±0.7 mm/m
±4°
< 4 s
–10 °C to +50 °C
–20 °C to +70 °C
2000 m
90 %
D)
2
2
Green
10
Red
1
0.8 mrad (full angle)
1/4", 5/8"
3 × 1.5 V LR6 (AA)
6 h
8 h
10 h
12 h
22 h
0.49 kg
112 × 55 × 106 mm
132 × 81 × 163 mm
Bosch Power Tools